Range of product |
Easy Modicon M100 |
Product or component type |
Logic controller |
[Us] rated supply voltage |
100...240 V AC |
Discrete I/O number |
16 |
Discrete input number |
I2...I5: 4 fast input I6...I8: 3 regular input I0...I1: 2 high speed input |
Discrete output number |
7 relay |
Discrete input voltage |
24 V |
Discrete input voltage type |
DC |
Discrete input current |
7 mA for regular input 7 mA for fast input 9 mA for high speed input |
Discrete output voltage |
24 V DC 220 V AC |
Discrete output current |
2 A |
Discrete output type |
Relay normally open |
Power consumption in VA |
30…40 VA at 100...240 V AC (with max I/O) |
I6...I8: 3 regular input
I0...I1: 2 high speed input
7 mA for fast input
9 mA for high speed input
220 V AC
Supply voltage limits |
85…264 V |
Voltage state 1 guaranteed |
>= 15 V for input |
Voltage state 0 guaranteed |
<= 5 V for input |
Network frequency |
50/60 Hz |
Inrush current |
50 A |
Input impedance |
3.3 kOhm for regular input 3.3 kOhm for fast input 2.81 kOhm for high speed input |
Response time |
10 ms turn-on Q0...Q6 terminal(s) for relay output 10 ms turn-off Q0...Q6 terminal(s) for relay output 35 µs turn-on I2...I5 terminal(s) for fast input 100 µs turn-off I2...I5 terminal(s) for fast input 5 µs turn-on I0...I1 terminal(s) for high speed input 5 µs turn-off I0...I1 terminal(s) for high speed input 35 µs turn-on I6...I8 terminal(s) for regular input 100 µs turn-off I6...I8 terminal(s) for regular input |
Configurable filtering time |
0 ms for input 3 ms for input 12 ms for input |
Output voltage limits |
30 V DC 250 V AC |
Maximum current per output common |
4 A at COM 0 4 A at COM 1 |
Electrical durability |
100000 cycles AC-12 240 V 480 VA resistive 100000 cycles DC-12 24 V 48 W resistive |
Switching frequency |
0.1 Hz with maximum load 5 Hz without maximum load |
Mechanical durability |
20000000 cycles for relay output |
Minimum load |
10 mA at 5 V DC for relay output |
Memory capacity |
1024 kB internal flash with 10000 instructions for backup of programs |
Data storage equipment |
32 GB micro SD card (optional) |
Execution time for 1 KInstruction |
0.3 ms for event and periodic task |
Execution time per instruction |
0.2 µs Boolean |
Exct time for event task |
60 µs response time |
Regulation loop |
Adjustable PID regulator up to 14 simultaneous loops |
Control signal type |
Quadrature (x1 x2 x4) at 60 kHz for fast input (HSC mode) Pulse/direction at 60 kHz for fast input (HSC mode) Single phase at 60 kHz for fast input (HSC mode) CW/CCW at 60 kHz for fast input (HSC mode) |
Counting input number |
2 fast input (HSC mode) at 60 kHz 32 bits |
Integrated connection type |
USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface |
Transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB |
Communication port protocol |
USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network |
Local signalling |
1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (green) for SL1 1 LED per channel (green) for I/O state |
Electrical connection |
removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block 4 terminal(s) for connecting the serial link1 Mini B USB 2.0 connectorfor a programming terminal removable screw terminal block 3 terminal(s) for connecting the 100-240 V AC power supply |
Maximum cable distance between devices |
Shielded cable: <10 m for fast input Shielded cable: <10 m for high speed input Unshielded cable: <150 m for output Unshielded cable: <50 m for regular input |
Insulation |
Between input and internal logic at 560 V AC Between fast input and internal logic at 560 V AC Between input groups at 560 V AC Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC |
Sensor power supply |
24 V DC |
Mounting support |
Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 |
Height |
90 mm |
Depth |
70 mm |
Width |
110 mm |
Product weight |
0.31 kg |
3.3 kOhm for fast input
2.81 kOhm for high speed input
Q0...Q6 terminal(s) for relay output
10 ms turn-off
Q0...Q6 terminal(s) for relay output
35 µs turn-on
I2...I5 terminal(s) for fast input
100 µs turn-off
I2...I5 terminal(s) for fast input
5 µs turn-on
I0...I1 terminal(s) for high speed input
5 µs turn-off
I0...I1 terminal(s) for high speed input
35 µs turn-on
I6...I8 terminal(s) for regular input
100 µs turn-off
I6...I8 terminal(s) for regular input
3 ms for input
12 ms for input
250 V AC
4 A at COM 1
240 V
480 VA
resistive
100000 cycles DC-12
24 V
48 W
resistive
5 Hz without maximum load
x2
x4) at 60 kHz for fast input (HSC mode)
Pulse/direction at 60 kHz for fast input (HSC mode)
Single phase at 60 kHz for fast input (HSC mode)
CW/CCW at 60 kHz for fast input (HSC mode)
Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB
Non isolated serial link: Modbus master/slave - RTU/ASCII or
SoMachine-Network
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (green) for SL1
1 LED per channel (green) for I/O state
removable screw terminal blockfor outputs
removable screw terminal block
4 terminal(s) for connecting the serial link1
Mini B USB 2.0 connectorfor a programming terminal
removable screw terminal block
3 terminal(s) for connecting the
100-240 V AC power supply
Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output
Unshielded cable: <50 m for regular input
Between fast input and internal logic at 560 V AC
Between input groups at 560 V AC
Non-insulated between inputs
Between output and internal logic at 1780 V AC
Between output groups at 1780 V AC
Between supply and internal logic at 1780 V AC
Top hat type TH35-7.5 plate or panel with fixing kit conforming to
IEC 60715
IP degree of protection |
IP20 with protective cover in place |
Product certifications |
CE |
Standards |
EN/IEC 61010-2-201 EN/IEC 61131-2 |
Electromagnetic compatibility |
Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 |
Shock resistance |
15 gn for 11 ms 30 gn for 6 ms |
Immunity to microbreaks |
10 ms |
Vibration resistance |
3.5 mm at 5…8.4 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 3 gn at 8.4…150 Hz on panel mounting |
Relative humidity |
10…95 % without condensation (in operation) 10…95 % without condensation (in storage) |
Ambient air temperature for operation |
0…55 °C (horizontal installation) |
Ambient air temperature for storage |
-25…70 °C |
pollution degree |
<= 2 |
Operating altitude |
0...2000 m |
Storage altitude |
0…3000 m |
EN/IEC 61131-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3
Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
30 gn for 6 ms
1 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
3 gn at 8.4…150 Hz on panel mounting
without condensation (in operation)
10…95 %
without condensation (in storage)
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
9.493 cm |
Package 1 Width |
12.157 cm |
Package 1 Length |
13.668 cm |
Package 1 Weight |
450 g |
Unit Type of Package 2 |
S03 |
Number of Units in Package 2 |
18 |
Package 2 Height |
30 cm |
Package 2 Width |
30 cm |
Package 2 Length |
40 cm |
Package 2 Weight |
8600 g |
Unit Type of Package 3 |
P12 |
Number of Units in Package 3 |
432 |
Package 3 Height |
95 cm |
Package 3 Width |
80 cm |
Package 3 Length |
120 cm |
Package 3 Weight |
215400 g |
Downloads
Schneider Electric_Modico...
PDF (604.6 KB) |
Added: 07 Jun 2025